Uniboot 跳线采用特殊的“圆形双芯”光缆,允许在单根光缆内进行双芯传输,并且与标准跳线相比,它减少了光缆管理空间。 Fiber-MART 的 LC Uniboot 光缆组件为高密度应用、数据中心、互连和交叉连接器、专用网络和场所安装提供最佳解决方案。
节省机柜和光缆槽高达 68% 的空间薄、灵活且与标准 LC 产品兼容 IEC、EIA/TIA 或 Telcordia 合规 RoHS 材料、REACH 和 SvHC 合规
OM4和OM3光纤模式的区别如下 1. OM4 专为 VSCEL 激光传输而开发,允许 10 Gig/秒的链路距离长达 550 m(OM3 为 300M)。 2. OM4的有效模态带宽是OM3的两倍以上。 3. OM4 跳线为 4700 MHz.km,OM3 跳线为 2000 MHz.km。
| Connector Type | LC Uniboot | Cable Diameter | 3.0 mm |
| Fiber Mode | OM3 50/125 m | Jacket Color | Aqua |
| Polish | UPC/UPC | Jacket Material | PVC |
| Fiber Type | Duplex | Cable Pull-out Force | 100N |
| Insertion loss | 0.3dB | Return loss | 30dB |
| Durability | 500 Cycles | Operating temperature | -40 to + 85C |
|
节省机柜和光缆槽高达 68% 的空间薄、灵活且与标准 LC 产品兼容 IEC、EIA/TIA 或 Telcordia 合规 RoHS 材料、REACH 和 SvHC 合规 |
|
| Designation | Fiber Dia.( m) | Type | Fast Ethernet 100BASE-FX | 1 Gbps Ethernet 1000BASE-SX | 1 Gbps Ethernet 1000BASE-LX | 10 Gbps Ethernet 10GBASE | 40 Gbps Ethernet 40GBASE-SR4/PLRL4 | 100 Gbps Ethernet 100GBASE-SR4/IR4 PSM |
| OM1 | 62.5/125 | Multimode | 2000m | 275m | 550m(MCP cable required) | 33m | Not supported | Not supported |
| OM2 | 50/125 | Multimode | 2000m | 550m | 550m(MCP cable required) | 82m | Not supported | Not supported |
| OM3 (Laser Optimized) | 50/125 | Multimode | 2000m | 550m | 550m | 300m | 100m | 100m |
| OM4 (Laser Optimized) | 50/125 | Multimode | 2000m | 550m | 550m | 400m | 150m | 150m |
| Singlemode | 9/125 | Singlemode | 2000m | 5km at 1310nm | 5km at 1310nm | 10km at 1310nm | 1km at PLRL4 | 2km at IR4 PSM |
| Fiber Mode | Single mode | Multimode |
| Insertion Loss | 0.30dB | 0.30dB |
| Return Loss | 50 dB (PC) | N/A |
| Return Loss | 60 dB (APC) | N/A |
| Durability | 1000 matings | 500 Cycles |
| Operating Temperature | -40 to + 85C | -40 to + 85C |
| Ferrule Hole Sizes | 125.0+1/-0 m Concentricity | 1.0 m |
| Ferrule Hole Sizes | 125.5+1/-0 m Concentricity | 1.0 m |
| Ferrule Hole Sizes | 126.0+1/-0 m Concentricity | 1.0 m |
工作温度:商业级/工业级/军品级可选
本产品为 北亿纤通 | F-tone Networks 产品线,详细信息,请联系我们的销售人员,谢谢! Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by Andxe System before they become applicable to any particular order or contract. In accordance with the Andxe System policy of continuous improvement specifications may change without notice.The publication of information in this data sheet does not imply freedom from patent or other protective rights of Andxe System or others. rther details are available from any Andxe System sales representative.