Fiberdo is the global brand of F-tone Networks

Mini Size PM Filter Coupler

Mini Size PM Filter Coupler

Mini Size Polarization Maintaining Filter Coupler

Features

Applications

Low Insertion Loss

EDFA & Raman Amplifier

High Return Loss

Fiber Sensor

High Extinction Ratio

Fiber Optical Instrument

Specifications

Parameter

Unit

Value

Type

1×2

2×2

Center Wavelength

nm

1550, 1310

1064

1550, 1310

1064

Operating Wavelength Range

nm

±40

±20

±40

±20

Max. Excess Loss

dB

0.7

0.8

1.0

1.2

Uniformity (only for 50/50)

dB

0.4

0.5

0.6

0.8

Coupling Ratio

dB

Min. Extinction Ratio

Both axis working

dB

18

Fast axis blocked

dB

22

Min. Return Loss

dB

50

Max. Optical Power (CW)

mW

300

Max.Tensile Load

N

5

Fiber Type

Input & Output Port

PM Panda fiber

Tap Port

PM Panda fiber or Single-mode fiber

Operating Temperature

-5~+70

Storage Temperature

-40~+85

*Above specifications are for device without connector.

*For device with connector, IL is 0.3dB higher, FTL is 5dB lower, and ER is 2dB lower.

*The default connector key is aligned to slow axis.

Ordering Information

MPMFC-1111-2334-555-666789-AAB (1×2 Type) / MPMFC-1111-2334-555-666789-AABB (2×2 Type)

1111 Wavelength:

1550=1550nm,1310=1310nm, 1064=1064nm, SSSS=Specify

2 Configuration:

3=1×2, 4=2×2

33 Tap ratio:

01=1%, 02=2%,…, 05=5%,…, 50=50%

4 Working Axis:

B=Both axis working, F=Fast axis blocked

555 Fiber type for Port 1, 3:

001=PM1550, 002=PM1310, 003=PM980, SSS=Specify

666 Fiber type for Tap:

001=PM1550, 002=PM1310, 003=PM980, 004=HI1060, 008=SMF-28E, SSS=Specify

7 Package Dimension:

0=φ3.2x30mm, 1=φ3.2x35mm, S=Specify

8 Pigtail Type:

0=bare fiber, 1=900μm loose tube

9 Fiber Length:

0.8=0.8m, 1.0=1m, S=Specify

AA Connector for Port 1, 3:

0=FC/UPC, 1=FC/APC, 2=SC/UPC, 3=SC/APC, N=None, S=Specify

BB – Connector for Tap:

0=FC/UPC, 1=FC/APC, 2=SC/UPC, 3=SC/APC, N=None, S=Specify

工作温度:商业级/工业级/军品级可选


本产品为 北亿纤通 | F-tone Networks 产品线,详细信息,请联系我们的销售人员,谢谢!Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by Andxe System before they become applicable to any particular order or contract. In accordance with the Andxe System policy of continuous improvement specifications may change without notice.The publication of information in this data sheet does not imply freedom from patent or other protective rights of Andxe System or others. Further details are available from any Andxe System sales representative.