特征 ※ 适用于包层直径125~400μm的光纤 ※ 精确对准,世界标准熔损 ※ 40/60mm管材熔接时间14s,加热时间24s ※ 适用于不同类型光纤(SM/MM/DS/NZDS) ※ 坚固机身,防水、防尘、防震 ※ 维护方便,更换电极方便 ※ USB接口用于软件升级、记录导出 ※ 支持4000/100组融合记录/融合图像 ※ 符合CE/Rohs国际标准
SM(G.652),MM(G.651),DS(G.653),NZDS(G.655)
Typical heating time
24 seconds for 60mm/40mm heating tube
X or Y single fiber image 125X,X and Y double image 62.5X
Dual high sensitivity camera, 5 inch 800*480 LCD Monitor
4000 groups data records and 100 group images
GUI menu interface, easy for operation
Adaptor, input: AC100-240V(50/60HZ),output: DC11-13.5V
>3000 times discharge (125um),>1000 times discharge (>125um)
Micro-USB 2.0 port, for software upgrading, records exporting
Altitude:0-5000m,Humidity:0-95%,Temperature:-10℃~+50℃;Wind:max 15m/s
155mm (L)×144mm (W)×155mm (H) /2.3kg
|
Model |
S-27-250 |
S-27-400 |
|
|
Alignment method |
Clad to clad |
||
|
Applicable fiber |
SM(G.652),MM(G.651),DS(G.653),NZDS(G.655) |
||
|
Cladding diameter |
125/250um |
400um |
|
|
Coating diameter |
250~1000µm |
||
|
Splicing program |
40 groups |
||
|
Operation mode |
Manual/ Automatic |
||
|
Auto- heating |
Available |
||
|
Typical splice time |
14 seconds |
||
|
Typical heating time |
24 seconds for 60mm/40mm heating tube |
||
|
Fiber magnification |
X or Y single fiber image 125X,X and Y double image 62.5X |
||
|
Viewing display |
Dual high sensitivity camera, 5 inch 800*480 LCD Monitor |
||
|
Data storage |
4000 groups data records and 100 group images |
||
|
Loss evaluation |
Available |
||
|
Tension test |
1.8~2.2N |
||
|
Interface |
GUI menu interface, easy for operation |
||
|
Power supply |
Adaptor, input: AC100-240V(50/60HZ),output: DC11-13.5V |
||
|
Electrode life |
>3000 times discharge (125um),>1000 times discharge (>125um) |
||
|
Terminals |
Micro-USB 2.0 port, for software upgrading, records exporting |
||
|
Operating condition |
Altitude:0-5000m,Humidity:0-95%,Temperature:-10℃~+50℃;Wind:max 15m/s |
||
|
Dimension/Weight |
155mm (L)×144mm (W)×155mm (H) /2.3kg |
||
工作温度:商业级/工业级/军品级可选
本产品为 北亿纤通 | F-tone Networks 产品线,详细信息,请联系我们的销售人员,谢谢! Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by Andxe System before they become applicable to any particular order or contract. In accordance with the Andxe System policy of continuous improvement specifications may change without notice.The publication of information in this data sheet does not imply freedom from patent or other protective rights of Andxe System or others. rther details are available from any Andxe System sales representative.