1.25G SFP optical transceiver module, support 1.25Gb/s and up to 180 km transmission
Features:
- Hot-Pluggable
- Duplex LC connector
- Up to 1.25Gb/s data rate
- 100GHz ITU Grid, C Band
- DWDM COOLED DFB transmitter, APD photo-detector
- SMF links up to 180km
- 2-wire interface for management specifications compliant with SFF 8472 digital diagnostic monitoring interface
- Power Supply :+3.3V
- Power consumption<1.5W
- Temperature Range: 0~ 70°C
- RoHS compliant
Applications:
- 1G Fibre channel
- DWDM Networks
- Fibre channel
FSPD-03D180-CXX
1.25Gb/s 180km DWDM SFP Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz, DWDM COOLED DFB&APD, Single mode
F-tone’s FSPD-03D180-Cxx is a very compact 1.25Gb/s optical transceiver module for serial optical communication applications at 1.25Gb/s. The FSPD-03D180-Cxx converts a 1.25Gb/s serial electrical data stream to 2.67Gb/s optical output signal and a 1.25Gb/s optical input signal to 1.25Gb/s serial electrical data streams. The high speed 2.67Gb/s electrical interface is fully compliant with SFI specification.
Absolute Maximum Ratings
|
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
|
StorageTemperature |
TS |
-40 |
|
+85 |
°C |
|
Case Operating Temperature |
TA |
0 |
|
70 |
°C |
|
Maximum Supply Voltage |
Vcc |
-0.5 |
|
4 |
V |
|
Relative Humidity |
FH |
0 |
|
85 |
% |
Electrical Characteristics (TOP= 0 to 70 °C, VCC = 3.135 to 3.465 Volts)
|
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Note |
|
Supply Voltage |
Vcc |
3.135 |
|
3.465 |
V |
|
|
Supply Current |
Icc |
|
|
450 |
mA |
|
|
Power Consumption |
P |
|
|
1.5 |
W |
|
|
Transmitter Section: |
||||||
|
Input differential impedance |
Rin |
|
100 |
|
Ω |
1 |
|
Tx Input Single Ended DC Voltage Tolerance (Ref VeeT) |
V |
-0.3 |
|
4 |
V |
|
|
Differential input voltage swing |
Vin,pp |
180 |
|
700 |
mV |
2 |
|
Transmit Disable Voltage |
VD |
2 |
|
Vcc |
V |
3 |
|
Transmit Enable Voltage |
VEN |
Vee |
|
Vee+0.8 |
V |
|
|
Receiver Section: |
||||||
|
Single Ended Output Voltage Tolerance |
V |
-0.3 |
|
4 |
V |
|
|
Rx Output Diff Voltage |
Vo |
300 |
|
850 |
mV |
|
|
Rx Output Rise and Fall Time |
Tr/Tf |
30 |
|
|
ps |
4 |
|
LOS Fault |
VLOS fault |
2 |
|
VccHOST |
V |
5 |
|
LOS Normal |
VLOS norm |
Vee |
|
Vee+0.8 |
V |
5 |
Note:
1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC.
2. Per SFF-8431 Rev 3.0
3. Into 100 ohms differential termination.
4. 20%~80%
5. LOS is an open collector output. Should be pulled up with 4.7k – 10kΩ on the host board. Normal operation is logic 0; loss of signal is logic 1. Maximum pull-up voltage is 5.5V.
Optical Parameters(TOP = 0 to 70°C, VCC = 3.135 to 3.465 Volts)
|
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Note |
|
Transmitter Section: |
||||||
|
Optical Wavelength-End Of Life |
λ |
X-100 |
X |
X+100 |
pm |
|
|
Optical Wavelength-Beginning Of Life |
λ |
X-25 |
X |
X+25 |
pm |
|
|
Average Optical Power |
Pavg |
+3 |
|
+7 |
dBm |
1 |
|
Laser Off Power |
Poff |
|
|
-30 |
dBm |
|
|
Extinction Ratio |
ER |
8.2 |
|
|
dB |
|
|
Transmitter Dispersion Penalty |
TDP |
|
|
3.0 |
dB |
|
|
Relative Intensity Noise |
Rin |
|
|
-128 |
dB/Hz |
2 |
|
Optical Return Loss Tolerance |
|
20 |
|
|
dB |
|
|
Receiver Section: |
||||||
|
Center Wavelength |
λr |
1480 |
|
1580 |
nm |
|
|
Receiver Sensitivity (OMA) |
Sen |
|
|
-37 |
dBm |
2 |
|
Los Assert |
LOSA |
-46 |
|
– |
dBm |
|
|
Los Dessert |
LOSD |
|
|
-38 |
dBm |
|
|
Los Hysteresis |
LOSH |
0.5 |
|
|
dB |
|
|
Overload |
Sat |
-8 |
|
|
dBm |
3 |
|
Receiver Reflectance |
Rrx |
|
|
-12 |
dB |
|
Note:
1. Average power figures are informative only Fibre channel
2. 12dB reflection.
3. Receiver overload specified in OMA and under the worst comprehensive stressed condition.
Timing Characteristics
|
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
|
TX_Disable Assert Time |
t_off |
|
|
10 |
us |
|
TX_Disable Negate Time |
t_on |
|
|
1 |
ms |
|
Time to Initialize Include Reset of TX_FAULT |
t_int |
|
|
300 |
ms |
|
TX_FAULT from Fault to Assertion |
t_fault |
|
|
100 |
us |
|
TX_Disable Time to Start Reset |
t_reset |
10 |
|
|
us |
|
Receiver Loss of Signal Assert Time |
TA,FX_LOS |
|
|
100 |
us |
|
Receiver Loss of Signal Deassert Time |
Td,FX_LOS |
|
|
100 |
us |
|
Rate-Select Chage Time |
t_ratesel |
|
|
10 |
us |
|
Serial ID Clock Time |
t_serial-clock |
|
|
100 |
kHz |
Order Information:
FSPD-03D180-Cxx XX: 100GHZ ITU Grid Wavelength
|
Part No. |
Central Wavelength(nm) |
Frequency (THZ) |
|
FSPD-03D180-C61 |
1528.77 |
196.1 |
|
FSPD-03D180-C60 |
1529.55 |
196.0 |
|
FSPD-03D180-C59 |
1530.33 |
195.9 |
|
FSPD-03D180-C58 |
1531.12 |
195.8 |
|
FSPD-03D180-C57 |
1531.90 |
195.7 |
|
FSPD-03D180-C56 |
1532.68 |
195.6 |
|
FSPD-03D180-C55 |
1533.47 |
195.5 |
|
FSPD-03D180-C54 |
1534.25 |
195.4 |
|
FSPD-03D180-C53 |
1535.04 |
195.3 |
|
FSPD-03D180-C52 |
1535.82 |
195.2 |
|
FSPD-03D180-C51 |
1536.61 |
195.1 |
|
FSPD-03D180-C50 |
1537.40 |
195.0 |
|
FSPD-03D180-C49 |
1538.19 |
194.9 |
|
FSPD-03D180-C48 |
1538.98 |
194.8 |
|
FSPD-03D180-C47 |
1539.77 |
194.7 |
|
FSPD-03D180-C46 |
1540.56 |
194.6 |
|
FSPD-03D180-C45 |
1541.35 |
194.5 |
|
FSPD-03D180-C44 |
1542.14 |
194.4 |
|
FSPD-03D180-C43 |
1542.94 |
194.3 |
|
FSPD-03D180-C42 |
1543.73 |
194.2 |
|
FSPD-03D180-C41 |
1544.53 |
194.1 |
|
FSPD-03D180-C40 |
1545.32 |
194.0 |
|
FSPD-03D180-C39 |
1546.12 |
193.9 |
|
FSPD-03D180-C38 |
1546.92 |
193.8 |
|
FSPD-03D180-C37 |
1547.72 |
193.7 |
|
FSPD-03D180-C36 |
1548.51 |
193.6 |
|
FSPD-03D180-C35 |
1549.32 |
193.5 |
|
FSPD-03D180-C34 |
1550.12 |
193.4 |
|
FSPD-03D180-C33 |
1550.92 |
193.3 |
|
FSPD-03D180-C32 |
1551.72 |
193.2 |
|
FSPD-03D180-C31 |
1552.52 |
193.1 |
|
FSPD-03D180-C30 |
1553.33 |
193.0 |
|
FSPD-03D180-C29 |
1554.13 |
192.9 |
|
FSPD-03D180-C28 |
1554.94 |
192.8 |
|
FSPD-03D180-C27 |
1555.75 |
192.7 |
|
FSPD-03D180-C26 |
1556.55 |
192.6 |
|
FSPD-03D180-C25 |
1557.36 |
192.5 |
|
FSPD-03D180-C24 |
1558.17 |
192.4 |
|
FSPD-03D180-C23 |
1558.98 |
192.3 |
|
FSPD-03D180-C22 |
1559.79 |
192.2 |
|
FSPD-03D180-C21 |
1560.61 |
192.1 |
|
FSPD-03D180-C20 |
1561.42 |
192.0 |
|
FSPD-03D180-C19 |
1562.23 |
191.9 |
|
FSPD-03D180-C18 |
1563.05 |
191.8 |
|
FSPD-03D180-C17 |
1563.86 |
191.7 |
工作温度:商业级/工业级/军品级可选
本产品为 北亿纤通 | F-tone Networks FT-81系列产品线,详细信息,请联系我们的销售人员,谢谢!Important Notice Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by Andxe System before they become applicable to any particular order or contract. In accordance with the Andxe System policy of continuous improvement specifications may change without notice.The publication of information in this data sheet does not imply freedom from patent or other protective rights of Andxe System or others. Further details are available from any Andxe System sales representative.